Product Overview

The Switch Terminal 400 Frame 10x16 lands ten 16 mm² branch circuits on the load side of one 400 A frame breaker - the densest outgoing block in this range, built for cabinets where rail space is already spoken for.
Ten feeders leaving one point is where panels get hard to live with: conductors cross, rear clamps hide behind front wires, and heat pools in the middle of the pack. This block is shaped against those three problems - a stepped outlet layout, a formed air path and a number on every circuit.
Technical Specifications
Rows below state this model's own figures; the rows flagged with an asterisk are shared across the series.
| Item | Specification |
|---|---|
| Function | Ten-circuit branch-outgoing terminal block for the load side of a 400 A frame breaker |
| Frame Rating | 400 A frame breakers and switch bodies |
| Outlets | 10 output circuits on one block |
| Wire Range | 10 to 16 mm² copper per outlet |
| Current Per Outlet* | 63 A with 16 mm² copper |
| Load Basis | Outlet values are clamp capacities; the block carries what its breaker feeds it, not ten simultaneous full loads |
| Rated Voltage | 400 V / 690 V AC |
| Contact Resistance | ≤ 0.25 mΩ |
| Outlet Layout | Patented high-low stepped arrangement; upper and lower rows offset so every clamp keeps an open approach |
| Circuit Marking | Outlets 1 to 10 permanently numbered by laser marking |
| Cooling | Formed air channels between the outlet rows vent heat from the conductor pack |
| Housing | High-impact polycarbonate (PC), molded for rigidity |
| Mounting | 35 mm DIN rail or base plate screw fixing |
| Protection | IP20 touch-proof |
| Operating Temp | −40 °C to +105 °C |
| Customization | Hole layout, marking scheme and plating produced to drawing; OEM and ODM available |
| MOQ* | 10 pieces |
| Lead Time* | 7 to 10 days standard; 15 to 20 days custom |
| Quality Guarantee* | 12 to 24 months, counted from the shipment date |
| Manufacturing Standard* | ISO 9001 quality management system |
| Delivery Ports* | Ningbo Port / Shanghai Port |
| Quote Turnaround* | Within 24 hours of receiving the enquiry |
* Rows flagged with an asterisk quote figures shared across this breaker terminal range; the datasheet issued with every quotation states the values specific to this model.
Core Advantages
Four answers to what goes wrong when ten outgoing feeders share one breaker.
A Stepped Layout That Keeps Every Clamp Reachable
The patented high-low arrangement offsets the ten outlets across two rows, so locking or releasing one conductor never jams against its neighbour or blocks the screwdriver reaching the next clamp.
Built-In Air Ducts Against Packed-Wire Heat
Open channels run between the rows, giving the dense conductor pack a continuous air path, so heat rises out of the block instead of pooling around the middle outlets.
Numbered Zones For Fast Fault-Finding
Every outlet carries a permanent laser-marked number, so a technician tracing circuit 7 lands on circuit 7 - no ringing out ten wires by hand during a shutdown.
Ten Circuits On One Moulded Body
The outgoing side sits on a single block that clips to a DIN rail or screws to the backplate, replacing a rail of loose single poles with their end brackets and markers.
A Stepped 10-Circuit Block vs A Flat Rail Of Single Terminals
The difference shows up the first time a fitter has to work on the back half of a full outgoing terminal.
| What Changes | This Stepped Block | A Flat Rail Of Single Terminals |
|---|---|---|
| Clamp access | Offset rows leave an open approach to every screw | Rear clamps hide behind the front row of conductors |
| Heat in the pack | Air channels between the rows vent rising heat | Conductors bunched at one height trap warm air |
| Circuit identification | A permanent number at every outlet | Slide-on markers fitted by hand, or none at all |
| Wiring discipline | One conductor per numbered position | Feeder order drifts as the rail fills up |
| Servicing | Release one outlet without touching its neighbours | Adjacent wires lifted just to reach one clamp |
| Footprint | One body on the breaker's load side | A full rail section plus end brackets and markers |
Application Scenarios
Where ten 16 mm² feeders leave one breaker, this is where the block goes.
High-Density Distribution Cabinet Building
Cabinet builders packing ten outgoing circuits onto a single 400 A frame breaker keep the outgoing side ordered without widening the enclosure.
Industrial Automation Control Centers
Control sections with many dense feeder groups get numbered, serviceable branch points that stay readable through revision after revision.
Retrofit And Upgrade Panels
When an existing cabinet gains circuits, the stepped block adds ten outlets without reworking the outgoing rail.
Frequently Asked Questions
Q: What does the stepped outlet layout change on the wiring floor?
A: Access. With the ten outlets split across offset high and low rows, every clamp screw keeps a clear approach, so locking and releasing one 16 mm² conductor never means lifting or working around its neighbours.
Q: How does the block cope with the heat ten conductors generate?
A: Two ways. Formed air channels between the outlet rows carry rising heat away from the pack, and the ≤0.25 mΩ contact resistance keeps joint heating low. The block is rated from −40 °C to +105 °C.
Q: Will it fit the 400 A frame breakers we build with?
A: It is made for the outgoing side of 400 A frame breakers and switch bodies. Name the breaker model when you enquire; the mounting fit is then checked dimension-for-dimension against that terminal drawing before anything ships - geometry decides, not brand names.
Q: How do we start an order?
A: Orders begin at 10 pieces; standard builds ship within ten days of confirmation and custom work within twenty. Include the breaker model and the quantities, and a priced reply reaches you inside one working day.


Hot Tags: switch terminal 400 frame 10x16, China switch terminal 400 frame 10x16 manufacturers, suppliers, factory, breaker terminals, MCB Matching Terminal 4x10, RCCB Matching Terminal 100 Type, Switch Terminal 400 Frame 10x16, Switch Terminal 400 Frame 3x16, Switch Terminal 400 Frame 6x16