Product Overview

The MCB Matching Terminal 4x10 is a DIN-rail MCB terminal block that sits at the row of miniature circuit breakers and turns one incoming supply into four independent 10 mm² branch circuits, one outlet against each MCB position.
A standard MCB terminal chamber is sized for a single conductor, so branching off one breaker usually means twisting or stacking wires inside that narrow clamp - a joint that relaxes with thermal cycling and can run hot enough to spark. This block gives every branch a clamp of its own, while the inlet side accepts either a cable or a comb busbar.
Technical Specifications
The rows below carry this model's published specification; asterisked rows at the foot are range-wide reference figures.
| Item | Specification |
|---|---|
| Function | Four-way distribution terminal feeding four 10 mm² branch circuits from one inlet, mounted at the MCB row |
| Configuration | 4 × 10 mm² outlets on 18 mm pole spacing |
| Inlet Cable Range | 16 – 35 mm² |
| Outlet Cable Range | 4 – 10 mm² |
| Rated Current | 63 A / 100 A, matched to the MCB frame the block feeds |
| Rated Voltage | 230 V / 400 V AC |
| Conductor Material | Tin-plated copper alloy |
| Housing Material | PA66, UL94 V-0 flame-retardant grade |
| Protective Cover | Flame-retardant transparent cover; outlets stay visible for inspection and guarded against accidental contact |
| Protection Degree | IP20 touch-proof terminals |
| MCB Interface | Standard 18 mm modular MCBs to DIN 43880 / IEC 60898; 1P, 2P, 3P and 4P layouts; 63 A and 100 A frames |
| Busbar Inlet Option | Finger-safe comb busbar, 18 mm pitch, pin or clamp type |
| Mounting | Clips onto 35 mm top-hat DIN rail (EN 50022); 4 modules, 72 mm overall |
| Inlet Screw Torque | 5 – 7 N·m (M6) |
| Outlet Screw Torque | 1.5 – 2.0 N·m (M4) |
| MOQ* | 10 pieces |
| Lead Time* | 7 to 10 days standard; 15 to 20 days custom |
| Quality Guarantee* | 12 to 24 months, counted from the shipment date |
| Manufacturing Standard* | ISO 9001 quality management system |
| Delivery Ports* | Ningbo Port / Shanghai Port |
| Quote Turnaround* | Within 24 hours of receiving the enquiry |
* Asterisked rows are range-wide reference figures shared across this breaker terminal family; model-specific values are confirmed on the datasheet issued with each quotation.
Core Advantages
Four features, each answering a failure the cramped breaker chamber produces.
Snaps Onto Mainstream MCB Modules
Pole pitch, module width and rail clip follow the standard 18 mm modular MCB layout, so every outlet lines up with the breaker above it by geometry alone - no measuring or shimming, whichever brand of MCB the panel carries.
One Clamp Per Conductor, Locked Against Loosening
Each of the four outlets carries its own frame-type screw clamp that traps stranded wire over the full contact face, holding the 1.5–2.0 N·m setting through vibration and heat instead of relying on pressure shared between conductors.
Transparent Cover, Inspection Without Contact
The flame-retardant cover keeps every branch in view so a maintenance round confirms seating and dressing with the lid in place, while IP20 touch-proof terminals protect the fitter working beside live adjacent circuits.
Comb-Busbar Ready Inlet
The inlet takes a finger-safe comb busbar at 18 mm pitch as an alternative to a 16–35 mm² cable, feeding all four outlets from one joint and cutting assembly time on repetitive panel lines.
A Dedicated Four-Way MCB Terminal vs Multi-Wire Termination In The Breaker Clamp
The two approaches differ in where the branch joints live and who can inspect them afterwards.
| What Changes | This Four-Way Terminal | Multi-Wire Wiring In The MCB Clamp |
|---|---|---|
| Conductors per clamp | One branch conductor per screw clamp | Two or more strands shared inside one narrow MCB terminal |
| Hold over time | Frame-type clamp keeps its torque setting in service | Shared pressure relaxes as strands and insulation creep |
| Failure mode | A loose branch stays a local re-tighten | A dropped conductor at the breaker can arc under load |
| Inspection | Cover-on visual check of every outlet | Joints hidden behind breaker bodies and tape |
| Feeding method | One inlet cable or one comb busbar | Jumper leads chained from breaker to breaker |
| Assembly habit | Clip on, land four cables, close the cover | Twist, tape and cram before the breaker even mounts |
Application Scenarios
Wherever four 10 mm² branches leave an MCB row, the block takes the joint load off the breakers themselves.
Residential Consumer Units
Apartment and housing CU builders land lighting, socket and small-power circuits in one tidy row directly below the MCBs.
Commercial Sub-Panels And Lighting Boards
Shopfitting and office fit-out panels gain four labelled branch points without extra terminal strips crowding the breakers.
MCB Assembly And Panel-Building Lines
Repeat-build lines standardise the outgoing side of the board: the same block, the same torque habit and the same cover check on every panel shipped.
Frequently Asked Questions
Q: Which breakers does it fit?
A: Standard 18 mm modular MCBs built to DIN 43880 / IEC 60898 in 1P, 2P, 3P and 4P layouts, 63 A and 100 A frames. Send your breaker model with the enquiry and alignment is confirmed against the module drawing.
Q: Can the inlet be fed from a comb busbar?
A: Yes. Finger-safe pin or clamp-type busbars at 18 mm pitch insert directly, so a single joint feeds all four outlets and panel wiring time drops accordingly.
Q: What torque do the terminals take?
A: The M6 inlet clamps take 5–7 N·m and the four M4 outlets 1.5–2.0 N·m. A calibrated driver keeps every branch at the same setting across a production run.
Q: What are the ordering terms?
A: Supply starts from 10 pieces; standard builds ship in seven to ten days and custom versions in fifteen to twenty. Send quantities and the quotation comes back within 24 hours.


Hot Tags: mcb matching terminal 4x10, China mcb matching terminal 4x10 manufacturers, suppliers, factory, RCCB Matching Terminal 100 Type, Switch Terminal 400 Frame 10x16, Switch Terminal 400 Frame 4x16, Switch Terminal 400 Frame 6x16, Switch Terminal 400 Frame 8x16, switch terminals