Product Overview

The Switch Terminal 400 Frame 4x16 is a direct bolt-on extension bar that expands the load-side connection of a 400 A frame moulded case circuit breaker into four independent branch circuits, each accepting 16 mm² copper.
Wiring four branches off one large breaker conventionally means adding a busbar, and a busbar means bolted joints that age into hot spots and re-tightening rounds. The bar cuts that stage out: its branch connections are formed in place, leaving only the four clamps that carry current.
Technical Specifications
| Item | Specification |
|---|---|
| Function | Direct bolt-on extension bar expanding one 400 A frame breaker connection into four branch circuits |
| Frame Rating | 400 A continuous duty, matching the breaker the bar is fitted to |
| Outlets | 4 output circuits on one bar |
| Wire Range | 16 mm² copper per outlet (6 to 4 AWG) |
| Current Per Outlet* | 63 A with 16 mm² copper |
| Base Material | High-conductivity electrolytic copper (E-Cu); H59/H62 brass option |
| Finish | Electro-tin plated standard; nickel plated optional; bare copper on request |
| Connection | Bolt-on stud to the breaker's terminal busbar; cage clamp for branch conductors |
| Torque Capability | Clamping hardware engineered to take full tightening torque without mechanical deformation |
| Mounting | Bolt-on to the breaker's own terminal pattern; hole spacing drilled to the 400-frame layout |
| Customization | Hole spacing, bolt size and plating thickness produced to drawing; OEM and ODM available |
| MOQ* | 10 pieces |
| Lead Time* | 7 to 10 days standard; 15 to 20 days custom |
| Quality Guarantee* | 12 to 24 months, counted from the shipment date |
| Manufacturing Standard* | ISO 9001 quality management system |
| Delivery Ports* | Ningbo Port / Shanghai Port |
| Quote Turnaround* | Within 24 hours of receiving the enquiry |
Core Advantages
Four design choices, each answering a failure mode of the layout this bar replaces.
Four Circuits Without An Add-On Busbar
It bolts straight onto the breaker's terminals with the branch connections formed in, so no separate busbar and no bolted intermediate joints ever enter the panel.
Hole Spacing Matched To The 400 Frame
Holes are drilled to standard 400 A frame terminal patterns; custom spacing, bolt sizes and plating thicknesses follow your drawing for OEM lines.
Staggered Outlets, No Crowded Lugs
The four entries are offset so each 16 mm² conductor gets its own clamp and clear phase separation - no lug stacking, no fight for room on one terminal.
More Contact Area, Lower Temperature Rise
The enlarged copper interface spreads current across a wider face than one lug, holding temperature rise down in continuous full-load service.
One-Piece 4-Hole Extension Bar vs Add-On Busbar Wiring
What separates the two layouts is the number of clamped and bolted joints a fitter creates per panel, and who controls them afterwards.
| What Changes | This Extension Bar | Add-On Busbar Wiring |
|---|---|---|
| Joints per four circuits | Four clamp points in total | Bolted busbar joints plus four terminal joints |
| Load path | Breaker to branch through one formed bar | Every branch crosses a busbar joint first |
| Cable entries | Four staggered outlets, one conductor each | Lugs stacked onto shared terminals |
| Panel space | One bar on the breaker's own footprint | Busbar length plus supports and a terminal row |
| Assembly work | Bolt on, then land the cables | Bar cut, drilled, insulated and mounted first |
| Loosening in service | One clamp set per branch on a fixed torque habit | Every added bolt is another point to re-tighten |
Material & Surface Treatment Options
Two base metals and three finishes cover the orders this bar ships in; settle the choice at the drawing stage.
Electrolytic Copper Or H59/H62 Brass
E-Cu conducts above 98% IACS and is the choice for heavily loaded distribution circuits; H59/H62 brass carries moderate loads at a lower material cost.
Tin, Nickel Or Bare Finish
Electro-tin is standard, keeping contact faces oxide-free and solderable; nickel suits humid or chemically aggressive plants; bare copper is available for welding or custom processing.
Application Scenarios
Where four 16 mm² branches leave one 400 A breaker, this is where the bar goes.
Medium Switchgear And MCC Panels
Panel builders standardising the outgoing side of 400 A breakers get four tidy branch points without designing a busbar for each cabinet.
Industrial Power Distribution Centers
Feeder cables running straight from a central breaker ride on the bar, with no extra busbar blocks crowding the enclosure.
Sub-Panels And Combiner Boxes
Compact electrical rooms and PV AC combiner boxes gain branch capacity inside the breaker's own footprint.
Frequently Asked Questions
Q: What does this bar take out of the panel?
A: The busbar-and-lug stack a four-branch layout otherwise needs on a 400 A frame breaker. The bar bolts straight to the breaker's terminal pattern and gives four 16 mm² outlets from one piece of copper.
Q: Will it fit the breakers on our assembly line?
A: It is drilled for standard 400-frame MCCB and ACB terminal patterns. Quote the breaker model in your enquiry and the hole spacing is verified against the terminal drawing before the order - by dimensions, not by brand names.
Q: Which material and finish should we order?
A: Electrolytic copper for heavily loaded circuits, H59/H62 brass where cost carries more weight. Electro-tin plating is standard; nickel for humid or chemically aggressive plants, bare copper for welding work.
Q: How do we order, and on what terms?
A: Supply starts from 10 pieces; standard builds ship in seven to ten days, custom work in fifteen to twenty. Include the breaker model and quantities and the quotation comes back inside 24 hours.


Hot Tags: switch terminal 400 frame 4x16, China switch terminal 400 frame 4x16 manufacturers, suppliers, factory, breaker terminals, MCB Matching Terminal 4x10, RCCB Matching Terminal 100 Type, Switch Terminal 400 Frame 10x16, Switch Terminal 400 Frame 4x16, Switch Terminal 400 Frame 6x16