Neutral Terminal 400A 25 To 70sqmm

Neutral Terminal 400A 25 To 70sqmm

Details:
The Neutral Terminal 400A 25 to 70sqmm is a robust dedicated neutral busbar terminal designed for large three-phase four-wire power distribution systems, industrial panels, photovoltaic and energy storage AC combiner boxes, and data center power systems where neutral conductors must carry currents up to 400A.

Send Inquiry
Description
Send Inquiry

Product Overview

product-800-533

The Neutral Terminal 400A 25–70sqmm is a heavy-duty neutral busbar terminal built for high-current three-phase four-wire systems. Accepting 25–70 mm² copper conductors, it delivers a low-impedance neutral connection in main distribution boards, generator output circuits, and industrial switchgear.

A massive copper conductor block and pressure-plate clamping keep contact resistance extremely low at full load, so the joint stays cool and stable even when sudden load surges hit the system - the exact condition where ordinary terminals overheat and melt.

 

Technical Specifications

 

Item

Specification

Rated Current

400A

Rated Insulation Voltage (Ui)

690V / 1000V AC

Rated Impulse Withstand (Uimp)

8 kV

Short-Time Withstand Current (Icw)

4 kA / 1s

Temperature Rise

≤ 50K at rated current (IEC 60947-7-1)

Main Conductor Range

25–70 mm² (Cu)

Branch Conductor Range

16–50 mm² (Cu)

Main / Branch Clamp Screw

M8 / M6 hex socket

Recommended Torque

10–14 N·m (main) / 5–7 N·m (branch)

Connection Type

Screw clamp with pressure plate

Conductor Type

Solid, stranded, finely stranded (Class 5/6) copper

 

Core Advantages

High Surge-Current Withstand

Short-time withstand of 4kA for 1 second absorbs the inrush from suddenly applied generator loads without contact deformation or welding.

Large-Area Copper Contact

Oversized copper block maximizes contact area, keeping contact resistance below 0.2 mΩ and heat generation minimal at 400A continuous current.

Pressure-Plate Clamping

Even clamping force across the conductor cross-section protects finely stranded cables from strand damage and keeps torque stable over years of thermal cycling.

Verified Thermal Margin

Temperature rise controlled within 50K at rated current per IEC 60947-7-1, providing a long-term safety margin for 24/7 industrial operation.

 

400A Neutral Terminal vs Ordinary Terminal Block

 

Comparison

Neutral Terminal 400A

Ordinary Terminal Block

Surge Current Withstand

4kA/1s tested

No rating; risk of melting under inrush

Conductor Range

25–70 mm²

Typically ≤ 16 mm²

Contact Structure

Large copper block + pressure plate

Small contact point

Temperature Rise

≤ 50K at 400A

Overheats at high continuous load

Design Standard

IEC 60947-7-1

General purpose

 

Professional Production Process
 

Copper bar cutting → CNC precision punching → thread tapping → deburring & chamfering → surface plating → 100% torque and dielectric testing. Every batch passes withstand-voltage and resistance checks before packing.

 

Material & Surface Treatment Options

 

Conductor Body

High-purity T2 copper block for maximum conductivity

01

Plating

Tin plating standard; nickel or silver plating optional for corrosive environments

02

Screws & Pressure Plates

Steel with zinc plating, hex socket for controlled torque

03

Custom plating and laser marking available per project requirements.

04

 

Application Scenarios

 

Generator Output & Neutral Connections

Handles the sudden load steps of genset startup, where inrush currents reach several times rated value and weak joints quickly burn out.

Main Distribution Boards

Central neutral bar for 400A-class three-phase four-wire panels in commercial and industrial buildings.

PV / Energy Storage & Data Centers

Reliable neutral termination in AC combiner boxes and UPS distribution where continuity is critical.

 

 

Frequently Asked Questions

 

 

Q:What conductor sizes does it accept?

A:Main conductors 25–70 mm² copper; branch conductors 16–50 mm². Solid, stranded, and finely stranded Class 5/6 cables are all supported.

Q:Can it survive generator inrush currents?

A:Yes. It is short-time tested at 4kA for 1 second and temperature-rise tested at full 400A per IEC 60947-7-1, specifically for genset and heavy inrush applications.

Q:Do you support OEM/ODM?

A:Yes. Custom hole counts, fixing dimensions, plating, and laser marking are available from drawings, with sample testing supported before bulk orders.

 

product-3840-2160
product-3840-2160

 

Hot Tags: neutral terminal 400a 25 to 70sqmm, China neutral terminal 400a 25 to 70sqmm manufacturers, suppliers, factory, Neutral Busbar 3x30 10Pole, Neutral Terminal 250A 16 To 50sqmm, Neutral Terminal 400A 25 To 70sqmm, Neutral Terminal 600A 35 To 95sqmm, Standalone Neutral Terminal 100A 10 To 35sqmm, Standalone Neutral Terminal 600A 35 To 95sqmm

Send Inquiry
Send Inquiry