Product Overview

The nylon cable gland metric m25 is the entry fitting for mid-size power cable. It passes a jacket of 13 mm to 18 mm through an M25 × 1.5 thread, seals the enclosure wall, and grips the cable so it cannot be pulled back out of the box. Outdoor distribution cabinets and PV inverter enclosures are where it earns its keep.
Cable entries are the first place water gets into an enclosure, and two failure modes account for most of it. The first is age: plain polyamide chalks and embrittles after a few summers in direct sun, and the seal loses its preload until the joint weeps. The second is mechanical: a cable pulled through a trench drags the jacket partly out of the seal, and once the seal is no longer compressed the waterproof rating is gone.
The housing is PA66 nylon with the UV stabilizer compounded into the polymer rather than applied as a coating, so it cannot wear off the outside. It is flame retardant and holds its rated properties from -40 °C to +100 °C on the standard EPDM seal. Body length is 35 mm, extended versions are available, and the seal compound can be specified as EPDM or silicone to suit the cable jacket and the ambient temperature at the entry.
Technical Specifications
The M25 × 1.5 thread is metric and is not interchangeable with a PG thread of similar outside diameter, so confirm the enclosure thread standard rather than the hole size. And a gland tightened onto a jacket at the very edge of its clamping range seals less reliably than one clamped nearer the centre of the range.
| Parameter | Specification |
|---|---|
| Thread Standard | Metric M25 × 1.5 |
| Thread Outer Diameter | 25 mm |
| Cable Clamping Range | 13 mm – 18 mm jacket diameter |
| Gland Length | Standard 35 mm (extended versions available) |
| Protection Rating | IP68 when properly installed to IEC 60529 |
| Housing Material | PA66 Nylon, UV-stabilized |
| Flame Retardancy | UL94-V2 standard grade / UL94-V0 premium grade |
| Seal Material | EPDM (standard) / Silicone (high-temp option) |
| Operating Temperature | -40 °C to +100 °C (EPDM) / -55 °C to +180 °C (Silicone) |
| Environmental Compliance | RoHS / REACH compliant |
| Thread Seal | O-ring or gasket between gland body and enclosure wall |
| Panel Thickness | 1–6 mm standard / 1–12 mm with the long-thread version (series figure) |
| Thread Length | Series publishes 15 mm standard and 20 mm long thread; M25 value confirmed on request |
| Recommended Panel Hole | Confirmed on request - the series publishes 32.5 mm for the M32 body |
| Wrench Hex Size | Confirmed on request (series publishes 36 mm for the M32 body) |
| Installation | Hand-tight plus a quarter turn with a spanner until the seal visibly compresses |
| Customization | OEM / ODM per customer drawing - thread size, seal compound and packaging |
| MOQ | Depends on configuration; trial orders negotiable |
| Quality Guarantee | 12–24 months from shipment date |
| Manufacturing Standard | ISO 9001 quality management system |
| Packaging | Standard export packaging; bulk cartons or OEM poly bags |
| Delivery Ports | Ningbo Port / Shanghai Port |
| Quote Turnaround | Within 24 hours |
Core Advantages
Four decisions do most of the work on a fitting that has to sit outdoors for a decade.
IP68 Sealing At Two Points, Not One
A multi-lip EPDM seal is compressed radially onto the cable jacket as the nut is tightened, and an O-ring or gasket between the body and the enclosure wall stops water tracking in along the mounting thread. Sealing both paths is what makes the rating hold on a wall-mounted box rather than just on a test bench.
01
UV Stabilizer In The Compound, Not On The Surface
The stabilizer is part of the PA66 formulation. There is no coating to scratch, chalk or wash off, so the housing keeps its mechanical properties through years of direct sunlight instead of going brittle at the thread root, which is where an aged nylon gland usually fails.
02
The Seal Is Also The Strain Relief
Because the compression seal grips the jacket, a pull on the cable loads the seal instead of the terminals inside the enclosure. That removes the separate cable clamp many panels otherwise need, and it removes the most common route to a failed seal, a jacket dragged partially out of the body.
03
One Gland Covers The 13–18 mm Middle Range
A single M25 body covers the mid-size power and control cables that sit between the M20 and M32 entries. For a panel builder or a distributor that means fewer part numbers on the shelf and fewer thread sizes on the drill sheet for the same cabinet range.
04
Wire Cage Terminal vs Traditional Brass Terminal
This heading is kept so the section matches the rest of the site. A cable gland has no wire cage the way a terminal block does; the interface here is a compression seal and grip on the cable jacket, so the comparison below sets that mechanism against the traditional brass gland it usually replaces.
| Point Of Comparison | PA66 Compression Gland (This Product) | Traditional Brass Gland |
|---|---|---|
| Cable interface | Multi-lip EPDM seal compressed onto the jacket by the gland nut | Brass compression ring or armour clamp, often with a separate sealing ring |
| Strain relief | The compression seal grips the jacket and takes the pull | Higher pull-out capacity; the usual choice for armoured cable |
| Earth continuity | None required - the housing is insulating | Metal path through the body; an earth tag or grounding nut is standard |
| Weight and cost per entry | Lighter, lower cost | Heavier and more expensive |
| Ageing outdoors | UV-stabilized PA66; the polymer is the part that ages | Does not degrade in UV, though the finish dulls |
| Salt-laden or chemically aggressive air | Stable, but seal and jacket compatibility must be checked | Nickel plating resists salt spray; the marine default |
| Torque and impact | Sufficient for hand-tight plus a quarter turn; over-torque deforms the seal | Higher mechanical strength; tolerates heavy tightening |
| Thread fit | Metric M25 × 1.5, not interchangeable with PG | Same caveat - metric and PG bodies do not interchange |
Professional Production Process
Five steps, with the thread and the seal seating checked on every batch.
Injection moulding - body, clamping nut and insert are moulded from UV-stabilized PA66 compound to the M25 × 1.5 thread profile.
Seal moulding - the multi-lip EPDM insert is moulded to the clamping range; silicone inserts are produced on the same tooling for the high-temperature version.
Assembly - seal insert, body and clamping nut are assembled and the thread is run through its full travel.
Inspection - thread gauge, clamping range and seal seating are checked on samples drawn from each batch and recorded.
Packing - glands are counted, then packed in bulk cartons or to your OEM poly bag and label specification.
Material & Surface Treatment Options
Three material decisions carry most of the cost and most of the service risk, so they are worth settling before the order is placed.
Housing Compound: PA66 Nylon, UV-Stabilized
The body is PA66 polyamide with the UV stabilizer compounded in, which is what allows an outdoor installation without a protective shroud. The same compound carries the flame-retardant package, and the housing is insulating, so no earth tag is needed at the entry.
Seal Compound: EPDM Standard Or Silicone High-Temp
EPDM is the standard seal and covers -40 °C to +100 °C, which suits ordinary outdoor cabinets in most climates. Silicone moves the range to -55 °C to +180 °C for entries close to a heat source, such as the DC side of an inverter or a driver housing with poor airflow.
Flame Retardancy Grade: UL94-V2 Or UL94-V0
UL94-V2 is the standard grade and satisfies most enclosure specifications. UL94-V0 is the premium grade, specified where the panel itself is held to V-0 or where the enclosure sits in a public or transit installation. The grade is a material choice, so it should be named on the order rather than assumed.
Application Scenarios
Four enclosure types where a mid-range nylon gland is the right entry.
Outdoor Distribution Cabinets And Feeder Pillars
Street furniture and construction-site distribution cabinets where several M25 entries take the outgoing ways. The insulating housing means the entry adds no exposed metal to a cabinet that is already earthed elsewhere.
Solar Junction Boxes And PV Inverter Enclosures
Array junction boxes and inverter enclosures, where the entry sees wide daily temperature swings and years of direct sun. The UV-stabilized housing and the silicone seal option are what make the same part work on a rooftop and at ground level.
Industrial Control Panels And Water Treatment Equipment
Process panels, pump control boxes and treatment plant cabinets, where washdown and humid air are routine. The thread seal keeps water from tracking in behind the body, which is where an enclosure leak usually starts.
Marine And Coastal Electrical Cabinets
Dockside and coastal installations where salt is carried in on the air. Nylon and EPDM handle the chemistry, and the compression grip holds the jacket against the constant movement a cable sees at a marina.
Frequently Asked Questions
Q: Which cable sizes does the M25 gland accept?
A: The clamping range is 13 mm to 18 mm jacket diameter, covering the mid-size power and control cables used on outdoor distribution boxes and inverter enclosures. Check your jacket diameter before ordering rather than the conductor size, since the seal works on the outer jacket.
Q: How is IP68 achieved, and will it still hold after a year outdoors?
A: Two seals do the work: a multi-lip EPDM seal compressed onto the jacket, and an O-ring or gasket between body and wall that stops water tracking along the thread. Both depend on correct tightening, a round unbonded jacket and a deburred panel hole.
Q: Will the nylon body survive years of direct sun?
A: The UV stabilizer is compounded into the PA66 rather than coated onto it, so it does not wear away. It resists the chalking and embrittlement plain polyamide shows after a few summers, and the silicone seal option extends the temperature range to -55 °C to +180 °C.
Q: What happens to the seal when the cable is pulled?
A: The gland nut compresses the seal radially onto the jacket, so the seal doubles as the strain relief and the pull loads the seal rather than the terminals inside the box. For armoured cable or very high pull-out loads, a brass gland remains the stronger choice.
Q: Can you supply other thread sizes, and how fast is a quote?
A: The series runs from M12 to M32 metric and PG11 to PG21, all available with OEM packaging and your own label. MOQ depends on the configuration. Send your thread standard, jacket diameter and quantity for a quote within 24 hours.



Hot Tags: nylon cable gland metric m25, China nylon cable gland metric m25 manufacturers, suppliers, factory, cable glands, Nylon Cable Gland Metric M12, Nylon Cable Gland Metric M25, Nylon Cable Gland PG11, Nylon Cable Gland PG21, waterproof enclosures