Two Inlet Four Outlet 35 To 70sqmm

Two Inlet Four Outlet 35 To 70sqmm

Details:
Our two inlet four outlet 35 to 70sqmm is a flagship dual‑redundant heavy‑duty power distribution block engineered for mission‑critical applications requiring dual independent power feeds with large cross‑section conductors from 35mm² to 70mm². It integrates two independent main incoming terminals (A/B dual feed) and four independent outgoing branch terminals into a single compact unit, providing efficient, safe and reliable redundant power distribution for data center dual‑feed architecture, energy storage systems with redundant battery clusters, industrial dual‑power supply systems, and telecom base station backup power distribution.

Send Inquiry
Description
Send Inquiry

Product Overview

product-800-600

Two Inlet Four Outlet 35 To 70sqmm is a dual-redundant heavy-duty distribution block that lands two electrically isolated A/B inlets and four outgoing branches in one body. It takes 35 mm² to 70 mm² copper cable directly, so a high-power incoming cabinet or a transformer secondary panel no longer needs two single-feed blocks wired side by side.

The wide-mouth wire cage is the point of the design. Large cross-section cable is stiff and awkward to bend, and a round brass post forces the installer to curve the conductor before a screw can bite. Here the conductor drops straight into an open cage from the front and the clamp closes over it, so the joint stays tight under vibration and thermal cycling.

Each incoming feed is rated 400 A, giving 800 A across the pair, and each of the four outlets is rated 100–160 A. Every branch re-terminates on its own, so one outlet can be reworked without disturbing the other three.

 

Technical Specifications

 

 

Parameter Value
Incoming Feeds 2 (A/B dual feed, electrically isolated)
Outgoing Branches 4
Wire Range 35 mm² – 70 mm² (copper)
Current Capacity 400 A per feed (800 A total)
Outlet Rating 100–160 A per outlet
Rated Voltage 1000 V AC/DC
Contact Resistance ≤0.35 mΩ
Dielectric Strength ≥2.5 kV
Creepage Distance (A/B isolation) ≥8 mm
Torque Rating ≥3.0 N·m
Housing Material PC, UL94 V-0
Operating Temperature -40 °C to +105 °C
Customization OEM / ODM supported per customer drawings
MOQ Depends on configuration; trial orders negotiable
Quality Guarantee 12–24 months from shipment date
Manufacturing Standard ISO 9001 quality management system
Packaging Standard export packaging
Delivery Ports Ningbo Port / Shanghai Port
Quote Turnaround Within 24 hours

 

Core Advantages

Four points that decide whether a 35–70 mm² dual feed can be wired inside a crowded cabinet.

Wide-Mouth Wire Cage Accepts 35–70 mm² Cable

The cage opens wide enough for a full 70 mm² conductor to enter straight, with no strand trimming at the bench and no pre-forming. A narrow post terminal forces the installer to bend stiff cable to a radius the panel often has no room for.

Direct Insertion Without Pre-Bending

Thick cable is hard to bend and the bend radius eats panel depth. Front entry keeps the conductor in its natural run, which shortens wiring time on site and cuts the chance of a badly seated strand at the joint.

High Clamping Force Against Pull-Out

The clamp bears on the full conductor rather than on a single screw point, so the cable resists pull-out and loosening under vibration. Rated torque is ≥3.0 N·m while contact resistance is held at ≤0.35 mΩ.

Compact Dual-Feed Body Saves Rail Space

Two feeds and four branches share one compact body instead of two single-feed blocks, cutting panel space by roughly 50% and removing the inter-block wiring that is a common source of error. A transparent cover with laser-etched A/B identification lets circuits be traced without opening the panel.

 

Wire Cage Terminal vs Traditional Brass Terminal

 

The difference shows up when the cable is inserted, and again at the first re-torque. 

Point Of Comparison Wire Cage Terminal (This Block) Traditional Brass Terminal
Cable entry Open cage; conductor enters straight from the front Round post or bar; conductor must be wrapped or looped
35-70 mm² cable Fits without pre-bending or strand trimming Stiff cable must be bent to reach the post
Clamping force Clamp closes over the full conductor Pressure applied at a single screw point
Contact stability Broad face contact, ≤0.35 mΩ Point contact, sensitive to how it was torqued
Re-termination Any of the 4 branches can be reworked on its own Rewiring one feed often disturbs the others
Dual-feed panel space One block, roughly 50% less rail space Two separate blocks plus inter-block wiring

 

 

Professional Production Process

Every unit follows the same five steps, and the test results are recorded per batch.

1. Busbar stamping and forming - copper bar is cut, punched and formed to the drawing.
2. Surface treatment - the plating confirmed for the order is applied before assembly.
3. Housing moulding - PC bodies are moulded to the UL94 V-0 flame rating.
4. Assembly - cages and terminals are seated and fixed in the moulded body, all four positions in register.
5. Testing - contact resistance verified at ≤0.35 mΩ and dielectric strength at ≥2.5 kV.

 

Material & Surface Treatment Options
 

Two decisions are worth settling before the order is placed.

Busbar And Conductor Parts

Copper busbar carries the 400 A per feed. Plating and surface treatment are set at order stage, so confirm the option you need against the drawing - it affects contact resistance and how the joint behaves in a damp or corrosive enclosure.

Flame-Retardant PC Housing

The body is PC rated UL94 V-0, and the block is rated from -40 °C to +105 °C. That range covers outdoor cabinets and enclosure interiors that heat up in service.

 

Application Scenarios

Three places where a 2-in / 4-out 35–70 mm² block earns its rail space.

 
 

Industrial Incoming Cabinets

High-power incoming cabinets fed from two sources need both feeds landed and four outgoing runs distributed without doubling the rail. The isolated A/B inlets keep the two supplies electrically separate all the way through the block.

 
 
 

Transformer Secondary Outgoing

On the secondary side the 35–70 mm² cable is stiff and the runs are short. Front-entry cages let a contractor land a full 70 mm² conductor without fighting a bend, and the 100–160 A outlets line up with typical branch protection.

 
 
 

Redundant Dual-Feed Systems

The same block suits data centre dual-feed architecture, energy storage cabinets with redundant battery clusters, and telecom backup distribution, where two independent feeds have to reach four branch circuits from one footprint.

 

 

 

Frequently Asked Questions

 

 

Q: What is this dual-feed distribution block used for?

A: It lands two independent supply feeds and distributes them to four branch circuits from one body. In practice it replaces two single-feed blocks and the wiring between them, which is why it is common in incoming cabinets and transformer secondary panels.

Q: What cable sizes does it accept?

A: Copper conductors from 35 mm² to 70 mm². The cage is sized so a full 70 mm² conductor enters from the front without pre-bending, and no strand trimming is needed.

Q: How much current can it carry?

A: 400 A per incoming feed, 800 A in total across the two feeds. Each of the four outlets is rated 100–160 A, and the block is rated 1000 V AC/DC.

Q: Are the two inlets really isolated from each other?

A: Yes. The A and B inlets run on electrically isolated busbars with a creepage distance of ≥8 mm, and the transparent cover is laser-etched with A/B identification so both circuits can be traced by eye.

Q: Do you support custom specifications, and what is the MOQ?

A: Outlet configuration, plating and mounting can be produced to your drawing under OEM or ODM terms. MOQ depends on the configuration and any tooling involved; trial orders for a new project are negotiable, and volume pricing applies at higher tiers.

Q: What about testing, packaging and delivery?

A: Every batch is tested for contact resistance at ≤0.35 mΩ and dielectric strength at ≥2.5 kV, with results recorded per batch. Units ship in standard export packaging and the nearest ports are Ningbo and Shanghai. Send your drawing with the required quantity for a quote within 24 hours.

 

product-3840-2160
product-3840-2160
product-3840-2160
 

 

Hot Tags: two inlet four outlet 35 to 70sqmm, China two inlet four outlet 35 to 70sqmm manufacturers, suppliers, factory, distribution terminals, Jack Up One Inlet Six Outlet 10 To 35sqmm, Jack Up One Inlet Two Outlet 10 To 25sqmm, Single Pole One Inlet Eight Outlet, Single Pole One Inlet Five Outlet, Single Pole One Inlet Six Outlet