Product Overview

Single Pole One Inlet Twelve Outlet splits one incoming feed into twelve numbered branch circuits from a single-pole body on 35 mm DIN rail.
The problem it answers is rail width. Twelve separate blocks, or twelve poles of a strip, need the full cabinet length to carry the same branches, and that long run is where cables start crossing.
Each outlet has its own entry point and a numbered position, so a circuit is read off its position instead of a tag. The transparent polycarbonate cover keeps loose screws, discoloured copper and heat visible while it stays closed.
Technical Specifications
Standard configuration for the single-pole twelve-outlet version. Cover ratings are this product's own published figures; electrical rows follow the series and are marked confirm.
| Item | Specification |
|---|---|
| Configuration | 1 pole, 1 inlet / 12 outlets |
| Inlet Wire Range | 10 mm² – 70 mm², solid or stranded copper |
| Outlet Wire Range | 1.5 mm² – 16 mm², solid or stranded copper |
| Insulation Resistance | > 100 MΩ at 500 V DC |
| Dielectric Withstand Voltage | 2.5 kV AC for 1 minute |
| Load Basis | Twelve outlets at 10 A sum to 120 A, inside the 125 A continuous total; the per-outlet figure is terminal capacity, not a simultaneous load |
| Cover Material | High-transparency polycarbonate (PC) |
| Impact Resistance | IK08, 5 J impact energy (IEC 62262) |
| Flame Retardancy | UL94 V-0 |
| Temperature Resistance | −40 °C to +120 °C |
| Protection With Cover Closed | IP20 - touch and finger protection, with no dust-sealing claim |
| Cover Transparency | At least 85% light transmission |
| Mounting | 35 mm DIN rail or panel screw fixation |
| Circuit Identification | Numbered positions, one dedicated conductor entry point per outlet |
| Customization | Custom labeling, mounting hole patterns and modified circuit counts per drawing; OEM and ODM available for volume orders |
| MOQ | 10 pieces |
| Lead Time | 7–10 days standard orders; 15–20 days custom orders |
| Quality Guarantee | 12–24 months from shipment date |
| Manufacturing Standard | ISO 9001 quality management system |
| Packaging | 20 pieces per carton |
| Delivery Ports | Ningbo Port / Shanghai Port |
| Quote Turnaround | Within 24 hours |
Core Advantages
Four reasons a single-pole 1-in / 12-out block earns its rail.
The branches sit through the depth of the body instead of along the rail, so the cabinet spends a short rail length on branching.
One pole covers twelve circuits, which removes the inter-block links and jumper wiring that separate blocks need.
At 85% light transmission the terminals stay readable through the PC cover, so a visual check needs no panel opening.
The same part snaps onto 35 mm DIN rail or fixes by panel screw, so one stock item suits a cabinet and a direct-mounted box.
Wire Cage Terminal vs Traditional Brass Terminal
Rail consumption separates the two approaches first; re-work separates them second.
| What Changes | Screw-Clamp Terminal On This Block | Traditional Brass Terminal Strip |
|---|---|---|
| Rail length for twelve branches | Twelve branches stacked through the depth of one body | Twelve separate blocks, or a long strip laid along the rail |
| Wiring between blocks | None - every branch taps the same body | Inter-block links and jumper wires to bridge the blocks |
| Conductor entry | One dedicated entry point at each numbered position | Conductors converge on a shared strip, so entries cross |
| Clamping | Screw-clamp terminal closes over the conductor | Pressure applied at a single screw point |
| Re-working one branch | One position loosens without disturbing the other eleven | A mid-strip change disturbs neighbouring circuits |
| Tracing a fault | The numbered position identifies the run | Relies on tags that fall off or fade |
| Inspection | Transparent cover, terminals readable while closed | Cover opened for an inspection |
| Rail left for devices | Narrow footprint, twelve circuits in one pole | The strip sets the minimum width of the allocation |
Professional Production Process
Each batch runs through six steps, signed off on measured results.
Bar stock sheared and pierced to the released drawing.
Burrs dressed and edges broken before the surface is prepared.
Conductive parts plated, thickness logged.
Cover moulded and checked for 85% light transmission.
Body moulded against the UL94 V-0 flame rating.
Routine test per batch: insulation above 100 MΩ at 500 V DC, dielectric 2.5 kV AC for one minute.
Material & Surface Treatment Options
Transparent Polycarbonate Cover
The cover is high-transparency PC rated UL94 V-0 and good for −40 °C to +120 °C. It gives IP20 touch protection and keeps the terminals readable, which makes a closed-cover check possible.
Tin Plating Rather Than Bare Copper
Plating keeps contact resistance low and holds off the oxidation bare copper develops in a warm panel.
Application Scenarios
Three cabinet types where the single-pole layout pays for itself.
High-Capacity Control Cabinets
Where a cabinet crowds its feeders onto a short rail, twelve branches from one pole body take less rail than four three-way blocks, with no inter-block wiring to route.
Power Distribution Boxes
In a distribution box the rail is short and cables arrive from several directions. One narrow body gives every cable its own entry, so runs stay parallel instead of crossing.
Solar Combiners And Lighting Control
The same block serves a solar combiner stringing twelve inputs, an LED lighting panel switching twelve circuits from one feed, and multi-storey metering cabinets.
Frequently Asked Questions
Q: Where is a single-pole twelve-outlet block specified?
A: It splits one incoming feed into twelve branch circuits from a single pole on DIN rail, so control cabinets, distribution boxes, solar combiners and metering cabinets avoid stacking smaller blocks.
Q: How much rail space does the single-pole layout actually save?
A: The twelve branches stack through the depth of one body rather than spreading along the rail, so the rail length spent on branching stays short. Inter-block links and jumper wiring are gone.
Q: What are the voltage and current ratings?
A: The series is rated 125 A continuous at 400 V AC, with 10 A at any one outlet and insulation resistance above 100 MΩ at 500 V DC. Dielectric withstand is 2.5 kV AC for one minute.
Q: Which conductor sizes and mounting options fit?
A: Inlet 10–70 mm², outlets 1.5–16 mm², solid or stranded copper. The body mounts on 35 mm DIN rail or by panel screw fixation.
Q: Can the block be customized, and what is the minimum order?
A: Labeling, mounting hole patterns and circuit counts are built to your drawing, and OEM or ODM is open on volume. Minimum order is 10 pieces, with 7–10 days on standard builds and 15–20 on custom. Send a drawing and the quote comes back within 24 hours.


Hot Tags: single pole one inlet twelve outlet, China single pole one inlet twelve outlet manufacturers, suppliers, factory, distribution terminals, Jack Up One Inlet Six Outlet 10 To 35sqmm, Single Pole One Inlet Five Outlet, Single Pole One Inlet Six Outlet, Single Pole One Inlet Twelve Outlet, Two Inlet Four Outlet 35 To 70sqmm