Product Overview

Single Phase Thirteen Meter Terminal puts thirteen electrically independent single-phase meter positions into one moulded body on a single main inlet, for the meter box that serves thirteen households.
Thirteen is the awkward count to buy for. Ready-made strips come in eight, ten, twelve, fifteen and eighteen ways, so a thirteen-household box is normally wired by pairing two blocks or cutting a longer strip down.
Either way a joint lands mid-run: the halves have to be linked across, the numbering starts again halfway, and the spare positions are stranded on two separate parts. This module removes that decision - thirteen positions, one part number, one continuous row of labels.
Spacing is held at 18 mm, the standard DIN module pitch, so the assembly lines up with the box rather than fighting it. The inlet takes 25 mm² to 70 mm² and each meter position 6 mm² to 16 mm².
Technical Specifications
Standard configuration of the thirteen-position single-phase version. Send your meter box drawing or panel schedule and we confirm fit, labelling and pricing within 24 hours.
| Item | Specification |
|---|---|
| Meter Positions | 13, electrically independent |
| System Type | Single-phase |
| Rated Voltage | 230 V AC * |
| Terminal Spacing | 18 mm, standard DIN module pitch |
| Main Inlet Cable Range | 25 mm² – 70 mm² |
| Branch Cable Range, Per Meter | 6 mm² – 16 mm² |
| Rated Current Per Meter | 63 A maximum |
| Total Aggregate Current | 250 A under balanced loading |
| Load Basis | 250 A is the continuous rating of the block as a whole, not thirteen meters each drawing 63 A at the same moment |
| Housing | Flame-retardant polycarbonate, UL94 V-0 * |
| Contact Resistance | ≤ 0.35 mΩ initial * |
| Dielectric Withstand | ≥ 2.5 kV for 1 minute * |
| Bypass | Independent at every meter position, live swap capable * |
| Heat Dissipation | Vented housing on natural convection channels; terminal spacing set for thermal isolation |
| Maximum Operating Temperature | 105 °C, continuous duty |
| Phase Layout | Thirteen positions divided five on L1, four on L2, four on L3 |
| Circuit Identification | Every position numbered, with Line, Neutral and Earth marked |
| Mounting | 35 mm DIN rail or screw fixing * |
| Customization | Position count, labelling and mounting hole pattern built to your drawing; OEM and ODM available on volume |
| MOQ | 10 pieces |
| Lead Time | 7 to 10 days standard; 15 to 20 days custom |
| Quality Guarantee | 12 to 24 months, counted from the shipment date |
| Manufacturing Standard | ISO 9001 quality management system |
| Packaging | Standard export packaging |
| Delivery Ports | Ningbo Port / Shanghai Port |
| Quote Turnaround | Within 24 hours |
Values marked with an asterisk are series reference figures shared across the single-phase meter terminal range on this site. Model-specific datasheets and test reports are available on request.
Core Advantages
Four points decide whether a thirteen-household meter box can be closed up and signed off.
Thirteen Positions, One Part Number
Strips stop at twelve and start again at fifteen. Here the count is exact: nothing to pair, nothing to cut, no position bought and left unused.
No Joint In The Middle Of The Run
Two blocks bolted end to end meet at a link that carries the whole downstream current. This row is continuous, held at 18 mm by the moulding.
One Inlet Sized For A Riser
A 25 mm² to 70 mm² inlet brings the riser cable to one point, instead of splitting it across two blocks with a jumper bridging the join.
Vented For Thirteen Meters At Once
The housing vents on natural convection channels and the positions are spaced for thermal isolation.
A Dedicated Thirteen-Position Module vs Assembled Terminal Strips
The difference is not in how a screw grips a conductor. It is in what happens where two parts meet.
| What Changes | This Thirteen-Position Module | Two Blocks Or A Cut-Down Strip |
|---|---|---|
| Matching the count | Thirteen positions from one part number | Eight plus five, or six plus seven; a fifteen-way cut down leaves two positions unusable |
| Where the two parts meet | Nowhere. One moulding, one row | A link or jumper bridging the join, carrying the whole downstream current |
| Numbering | One run of numbers, 1 to 13 | The count restarts at the second block, so two circuits end up with the same number |
| Position spacing | Held at 18 mm at all thirteen | Set block by block, and it drifts at the join |
| Phase balance | Five on L1, four on L2, four on L3, laid out on the drawing | Depends how the two blocks happen to be split on site |
| Live parts | Behind one closed flame-retardant moulding | Two mouldings, with an exposed link between them |
| Adding a circuit later | A further block clipped alongside | Spare positions stranded on two different parts |
| Tender and spares | One part number to quote, stock and reorder | Two part numbers, a link, fasteners and a modified strip |
Professional Production Process
Four stages per batch, with the position count and the pitch checked as tooled features.
Copper bar cut and the thirteen tap points punched to the drawing, then deburred.
Degreased, then tin plated to the drawing thickness.
Body moulded for thirteen positions, with the rail clip, screw bosses and the 18 mm pitch formed in the same shot.
Every position checked for full screw travel, with electrical results logged per batch.
Material & Surface Treatment Options
Two choices decide how the block reads after a few years in a warm meter room.
The Moulding Behind The V-0 Grade
The body is flame-retardant polycarbonate rated UL94 V-0: a specimen self-extinguishes once the flame is removed. That covers flame spread only; smoke generation is a separate test and no report is published for it here.
Tin On The Copper Busbar
Contact faces are tinned copper, which keeps the oxide film that bare copper builds up in a warm, damp meter room off the clamping face and the screw thread.
Application Scenarios
Three settings where the count is thirteen and the box is already tight.
Thirteen-Household Residential Floors
Floor-level meter cabinets in apartment blocks where one floor, or one riser, serves thirteen dwellings.
Dormitory And Staff Meter Rooms
Student dormitories and staff blocks metered in groups of thirteen rooms.
Small Commercial Tenancies
Retail levels and small commercial buildings sub-metering thirteen tenant units from one supply point.
Frequently Asked Questions
Q: Why buy a thirteen-position module instead of two smaller blocks?
A: Because the join between two blocks is where the current and the numbering meet. One body keeps thirteen positions on 18 mm centres in one continuous run, numbered 1 to 13, with no link to torque.
Q: What does the 250 A figure cover, against 63 A per meter?
A: 250 A is the continuous rating of the block as a whole under balanced loading, not thirteen meters each pulling 63 A at once. The 63 A is the capacity of a single meter position, so size the inlet against the diversity you expect.
Q: Can one meter be changed without cutting supply to the other twelve?
A: Yes. An independent bypass sits at every meter position, so one meter can be isolated and swapped without interrupting the supply to the other twelve.
Q: Will it fit our meter box, and what cable sizes does it take?
A: Thirteen positions at 18 mm centres occupy about 234 mm, and the inlet needs room for a 25 to 70 mm² conductor; each meter takes 6 to 16 mm². Send the box drawing and the panel schedule and we confirm the fit, the phase layout and the price within 24 hours.


Hot Tags: single phase thirteen meter terminal, China single phase thirteen meter terminal manufacturers, suppliers, factory, One Inlet Fifteen Outlet Block, One Inlet Thirteen Outlet Block, Single Phase Fifteen Meter Terminal, Single Phase Four Meter Terminal, Single Phase Nine Meter Terminal, Single Phase Sixteen Meter Terminal